Ultrathin-strut stents – towards zero stent-related events?

AsiaIntervention 2025;11:e97-e98 | 10.4244/AIJ-E-25-00004

Sripal Bangalore1, MD, MHA

1. Division of Cardiology, Department of Medicine, New York University Grossman School of Medicine, New York, NY, USA

While the development of metallic stents revolutionised percutaneous coronary intervention (PCI) and solved the problems of acute recoil and vessel closure, thus making the acute results safer, it brought about a new stent-related issue of restenosis related to inflammation caused by the metal struts. The search for a solution to this problem led to the first-generation drug-eluting stents (DES), which reduced restenosis but created a new problem of impaired vascular healing, leading to late and very late stent-related events. Furthermore, progress in biomaterials, from stainless steel to cobalt/platinum chromium, allowed for thinner struts while maintaining radial strength and radiopacity. In parallel, the development of biocompatible polymers and advanced polymer-coating technology led to further development of newer stent technology – the second-generation DES − with faster healing of endothelium. For over a decade, other developments, including bioabsorbable polymers and polymer-free DES, while showing non-inferiority, failed to deliver on the promise of late superiority (after bioabsorption of the polymer)1. Technological advancements, including laser-cut stents, led to the development of ultrathin-strut DES (<70 μm)2, and meta-analyses have shown clinical superiority of ultrathin-strut DES over thin-strut DES2. These platforms have strut thicknesses between 50 μm and 65 μm: changes in stent design retain adequate radial strength despite the ultrathin strut; they have a bioresorbable polymer and elute sirolimus. Whether the strut thinness, the bioresorbable polymer, the drug, or their combination is responsible for the superiority has been debated3.

In this issue of AsiaIntervention, Protopopov et al present the results of the S-FLEX Russia registry evaluating the ultrathin-strut Supraflex Cruz sirolimus-eluting stent (Sahajanand Medical Technologies Ltd.) in a real-world all-comers Russian cohort of 522 patients undergoing PCI. In a cohort with 24% of patients with diabetes, 38% with multivessel disease, 21% with moderate to severe calcification, and only 36% undergoing post-dilatation, and with data on intravascular imaging not reported (and likely very low), stent failure events were extremely low. There was 1 patient (0.2%) with stent thrombosis and 5 patients (1%) with target lesion revascularisation, with a target lesion failure (TLF) rate of 3.1% at 1 year, consistent with other registry data from the same stent platform4.

While it is tempting to indirectly compare these rates to other platforms, this is fraught with limitations due to differences in the enrolled cohort, event definition, reporting, and adjudication. Nevertheless, the results continue to be encouraging despite the less-than-optimal PCI performed to current standards, including the very low use of intravascular imaging. While the ultrathin-strut platform and stent design can by itself significantly improve clinical outcomes, the higher rate of events in complex coronary disease, including bifurcation, is still an attestation of the need to optimise PCI using intravascular imaging5.

Will we ever have zero stent-related events? Stent-related events can be broadly categorised into events directly related to the stent or those indirectly related to the stents or due to patient characteristics. The ones directly related to the stent include endothelial damage; inflammation due to a foreign body reaction around struts/polymer, resulting in delayed re-endothelialisation, neoatherosclerosis, and longer-term increase in smooth muscle cell proliferation resulting in restenosis; flow disturbances around the struts increasing the risk of stent thrombosis; and metal ion leak over the long run resulting in chronic inflammation. The thinner struts and better polymers address many of these issues with lower inflammation, faster re-endothelialisation, and laminar flow around the struts reducing the risk of stent thrombosis/restenosis. However, it is not clear if making the struts even thinner would provide any incremental benefit. Intravascular imaging-guided post-PCI optimisation has been shown to improve clinical outcomes6. Whether this benefit is also seen in patients undergoing implantation of ultrathin-strut stents is not known. However, stent malapposition or underexpansion can increase the effective strut thickness and thereby negate any beneficial effect of ultrathin-strut stents, and as such, intravascular imaging-guided optimisation should theoretically help. A dual-therapy CD34 antibody-covered SES (dual-therapy stent [OrbusNeich]), which is an SES with CD34 antibodies immobilised on its luminal surface to capture circulating endothelial progenitor cells and promote early endothelialisation, has been tested to reduce stent-related events, including neoatherosclerosis. However, the rate of target lesion revascularisation was higher when compared with second-generation DES7, likely due to thicker struts (100 microns) and the potential differentiation of endothelial progenitor cells into smooth muscle cells.

One other potential disadvantage of the current metallic DES platform is the “caging” of the artery due to the metallic scaffolding inhibiting natural pulsatility, vasomotion, and adaptive remodelling, the relative contribution of which to stent failure is not clear. To address this, bioabsorbable scaffolds were developed to uncage the artery after bioabsorption but, so far, have failed to prove superiority over metallic DES. The DynamX coronary bioadaptor system (Elixir Medical) is a novel platform that can unlock and provide dynamic support to the artery, allowing it to regain its natural pulsatility and vasomotion. In the INFINITY-SWEDEHEART trial comparing the DynamX bioadaptor versus the zotarolimus-eluting DES (Resolute Onyx and Onyx Trustar [Medtronic]), the DynamX bioadaptor was non-inferior to contemporary DES for TLF at 1 year. Interestingly, in a prespecified landmark analysis after 6 months (when uncaging happens), the rate of TLF was lower with the DynamX bioadaptor compared with contemporary DES8. Longer-term follow-up is awaited. Finally, stent failure or vessel failure are also related to a host of patient-related factors including comorbidities (advanced age, diabetes and chronic kidney disease).

The near future incremental advances in PCI with the potential to reduce clinical events will likely come from appropriate lesion selection, optimal stent implantation using a combination of physiology and intravascular imaging with artificial intelligence application, and advances in medical therapy, and will less likely be due to any incremental changes in stent design. Up until that point, the incremental clinical benefit observed with ultrathin-strut platforms, including that of the Supraflex Cruz, should challenge prior completed trials, including the inferior results seen with PCI (using the TAXUS [Boston Scientific] or CYPHER [Cordis Corporation] stents) compared with coronary artery bypass surgery (CABG) in patients with diabetes in the FREEDOM trial. In fact, the TUXEDO-2 trial, enrolling a FREEDOM-like cohort, has just completed enrolment and will provide further insights into the outcomes with modern DES versus the performance goal of CABG from FREEDOM9. While aiming for zero stent-related events is likely unrealistic, we are slowly but surely chipping away at stent-related events, making PCI safer and longer-lasting despite an ever-increasing patient complexity. In the meanwhile, let us not forget the basics of appropriate patient/lesion selection, optimising PCI outcomes with intravascular imaging, maximising medical therapy, and encouraging a healthy lifestyle.

Conflict of interest statement

S. Bangalore reports grants and personal fees from Abbott; and personal fees from Boston Scientific, Biotronik, Pfizer, Amgen, Inari Medical, Truvic, Recor Medical, and Reata outside of the submitted work.

Share

References

  • Bangalore S. The Elusive Late Benefit of Biodegradable Polymer Drug-Eluting Stents. Circulation 2019;139:334-6
  • Bangalore S, Toklu B, Patel N, Feit F, Stone GW. Newer-Generation Ultrathin Strut Drug-Eluting Stents Versus Older Second-Generation Thicker Strut Drug-Eluting Stents for Coronary Artery Disease. Circulation 2018;138:2216-26
  • Bangalore S, Finn AV. Is this the end of the ultrathin-strut hypothesis? EuroIntervention 2024;20:e625-6
  • Protopopov A, Litvinyuk N, Stolyarov D, Rashytov D, Krestyaninov O, Badoyan A, Maiskov V, Samochatov D, Shestov D, Skrypnik D, Kostin A. Clinical safety and performance of a biodegradable polymer-coated sirolimus-eluting stent in an all-comers population: results from the S-FLEX Russia registry AsiaIntervention 2025;11:101-109
  • Ezenna C, Krishna MM, Joseph M, Ibrahim S, Pereira V, Jenil-Franco A, Nanna MG, Bangalore S, Goldsweig AM. Optical Coherence Tomography vs. Angiography Alone to Guide PCI for Complex Lesions: A Meta-Analysis of Randomized Controlled Trials Circ Cardiovasc Interv 2025;
  • Kuno T, Kiyohara Y, Maehara A, Ueyama HA, Kampaktsis PN, Takagi H, Mehran R, Stone GW, Bhatt DL, Mintz GS, Bangalore S. Comparison of Intravascular Imaging, Functional, or Angiographically Guided Coronary Intervention. J Am Coll Cardiol 2023;82:2167-76
  • Ndunda P, Vindhyal MR, Muutu T, Fanari Z. Clinical Outcomes of the Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Stent Versus Standard Drug-Eluting Coronary Stents: A Meta-Analysis. Cardiovasc Revasc Med 2020;21:213-21
  • Erlinge D, Andersson J, Fröbert O, Törnerud M, Hamid M, Kellerth T, Grimfjärd P, Winnberg O, Jurga J, Wagner H, Zwackman S, Adielsson M, Alström P, Masoe E, Ulvenstam A, Millgård J, Böhm F, Held C, Renlund H, Oldgren J, Smits PC, Elek C, Abizaid A, James S. Bioadaptor implant versus contemporary drug-eluting stent in percutaneous coronary interventions in Sweden (INFINITY-SWEDEHEART): a single-blind, non-inferiority, registry-based, randomised controlled trial. Lancet 2024;404:1750-9
  • Kaul U, Arambam P, Sinha SK, Abhaichand R, Parida AK, Banker D, Mody R, Khan A, Sharma R, Moorthy N, Chandra S, Koduganti SC, Garg R, Sarma PR, Agrawal DK, Reddy KMK, Bangalore S. Rationale and design of the TUXEDO-2 India study: Ultra-Thin strUt Supraflex Cruz versus XiencE in a Diabetic pOpulation with multi-vessel disease-2. Am Heart J 2023;256:128-38

Volume 11 – Number 2

View full issue

Download this article
Authors
  • Sripal Bangalore
AsiaIntervention
  • Readers
    • Archives
    • Subscribe to the newsletter
    • Contact us
  • About the journal
    • Overview
    • Editorial Board
    • Masthead
  • Services
    • Advertising in AsiaIntervention
    • Article reprints
    • Publication calendar
    • Rights & Permissions
  • Authors
    • Authors guidelines
    • Submit your paper
  • Legal
    • Disclaimer
    • Cookies Policy
    • Privacy Policy
    • Legal Notice
  • Follow us
    • Facebook
    • X
    • LinkedIn
Online ISSN 2491-0929 - Print ISSN 2426-3958
© 2015-2025 Europa Group - All rights reserved